Glycerol GK Assay Kit

The Glycerol GK test kit is a simple, reliable and accurate method for the measurement and analysis of glycerol in beverages, foodstuffs and other material. Based on use of ADP-glucokinase and increase in absorbance on conversion of NAD+ to NADH. Suitable for manual, auto-analyzer and microplate formats.
SKU: 5WZZZZZ2042
$148.00

The Glycerol GK test kit is a simple, reliable and accurate method for the measurement and analysis of glycerol in beverages, foodstuffs and other material. Based on use of ADP-glucokinase and increase in absorbance on conversion of NAD+ to NADH. Suitable for manual, auto-analyzer and microplate formats.

 

Advantages

• Novel tablet format for increased stability

• Very competitive price (cost per test)

• All reagents stable for > 2 years as supplied

• Very rapid reaction

• Positive reaction (assay proceeds with an increase in absorbance)

• Mega-Calc™ software tool for hassle-free raw data processing

• Standard included

• Suitable for manual, microplate and auto-analyzer formats

 

Principle:

(glycerokinase)

(1) Glycerol + ATP → L-glycerol-3-phosphate + ADP

(ADP-GK)

(2) ADP + D-glucose → G-6-P + AMP

(glucose-6-phosphate dehydrogenase)

(3) G-6-P + NAD+ → gluconate-6-phosphate + NADH + H+

Kit size: 70 assays (manual) / 700 (microplate) / 600 (auto-analyzer)

Method: Spectrophotometric at 340 nm

Reaction time: ~ 7 min

Detection limit: 0.37 mg/L

 

DATA BOOKLET 

SDS 

MEGA-CALC 

The Glycerol GK test kit is a simple, reliable and accurate method for the measurement and analysis of glycerol in beverages, foodstuffs and other material. Based on use of ADP-glucokinase and increase in absorbance on conversion of NAD+ to NADH. Suitable for manual, auto-analyzer and microplate formats.

 

Advantages

• Novel tablet format for increased stability

• Very competitive price (cost per test)

• All reagents stable for > 2 years as supplied

• Very rapid reaction

• Positive reaction (assay proceeds with an increase in absorbance)

• Mega-Calc™ software tool for hassle-free raw data processing

• Standard included

• Suitable for manual, microplate and auto-analyzer formats

 

Principle:

(glycerokinase)

(1) Glycerol + ATP → L-glycerol-3-phosphate + ADP

(ADP-GK)

(2) ADP + D-glucose → G-6-P + AMP

(glucose-6-phosphate dehydrogenase)

(3) G-6-P + NAD+ → gluconate-6-phosphate + NADH + H+

Kit size: 70 assays (manual) / 700 (microplate) / 600 (auto-analyzer)

Method: Spectrophotometric at 340 nm

Reaction time: ~ 7 min

Detection limit: 0.37 mg/L

 